Load Volume Scanner Specifications

 

General Specifications

Measurement Range (per tray)

0 – 130 m3 / 0 – 170 yd3
(0.5 – 65 m3 for trade legal use within New Zealand.
1 – 35 m3 for trade legal use within Australia)

Measurable Vehicle Types

Conventional (rectangular bodied) open tray on-road trucks, truck-trailers, semi-trailers (articulated) and bottom dumpers (bottom dump, centre dump); Off-highway dumpers, underground mine trucks, rigid body dump trucks and articulated dump trucks (max 3.3m wide, 4.2m high for standard LVS system. Custom mounting required for larger trucks); solid sided rectangular tractor trailers.

Measurable Tray Capacity

1.5 – 130.0 m3 / 2.0 – 170.0 yd3
(minimum 3.0 m3 for trade legal use within New Zealand)

Measurable Load Types

Flowable solids (particulate bulk materials) including:
rock aggregates, gravel, lightweight aggregates, sand, soil, clay, spoil, compost, bark, wood-chip, mulch and other garden/landscaping specialty mixes, fertilizer, shredded scrap steel/waste.

Maximum Load Particle Diameter (average)

200 mm / 7.8"

Measurement Resolution

0.1 m3 / 0.1 yd3
(0.05  m3  below 2.5  m3 measured volume for New Zealand only)

Typical Measurement Accuracy

Better than 1% to limit of resolution

Vehicle Speed (during scanning)

0.5 – 6.0 km/h / 0.3 – 3.7 mph

Power Requirements

110 – 240VAC, 50/60Hz, 4A max

Laser Protection Class

Class 1 (eye-safe)

Clearance (from Ground)

5.0 m / 16.4' minimum (depends on mounting system and type of vehicles to be scanned).

 

Rated Operating Conditions

Operating Temperature

-30 – 50 oC / -22 – 122 oF (Scan Head, LED Message Board)

0 – 45 oC / 32 – 113 oF (Operator Interface console, printer)

Minimum Visibility

50 m / 164' (dense fog)

Maximum Scan-Track Gradient

5 degrees (9%)

Maximum Scan-Track Camber

3 degrees (5%)

 